Kontron pITX-E38 Manuale Utente Pagina 48

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 61
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 47
KTD-N0904-D Page 46 BIOS - Advanced
pITX-E38 Users Guide
Hardware Monitor
Phoenix SecureCore Technology Setup
Advanced
Hardware Monitor Item Specific Help
Hardware Monitor
Board Temp [ºC]:
CPU Control Temp [ºC]:
Internal CPU Temp [ºC]:
Fan Speed [RPM]:
Fan Trip Point [ºC]:
Trip Point Speed [ % ]:
Fan Poles :
[32]
[33]
[24]
[4810]
[30]
[ 50]
[4]
Temperature where fan accelerates.
Range 20 80 C.
F1
Help
↑↓
Select Item
+/-
Change Values
F9
Setup Defaults
Esc
Exit
←→
Select Menu
Enter
Select Sub-Menu
F10
Save and Exit
Function
Selection
Description
Fan Trip Point 20, 21, …, 30, …, 80
Temperature where fan accelerates.
Range 20 80 C.
Trip Point Speed 30, 31, …, 50, …, 100
Fan speed at trip point in %. Minimum value
is 30.
Fan Poles
2
4
6
The number of pole pairs inside the fan. Ex:
Fan poles=4 generates 2 pulses every one
rotation.
Vedere la pagina 47