Pagina 2 - Customer Service

ix AM4210www.kontron.comSafety RequirementsThe following safety precautions must be observed when installing or operating the AM4210. Kontron assumes

Pagina 3 - Table of Contents

xAM4210www.kontron.comPrefaceHow to Use This GuideThis user's guide is designed to be used as step-by-step instructions for installation, and as

Pagina 4

xi AM4210www.kontron.comAdvisory ConventionsSeven types of advisories are used throughout the user guides to provide helpful information or to alert y

Pagina 5

xii AM4210www.kontron.comUnpackingFollow these recommendations while unpacking:• Remove all items from the box. If any items listed on the purchase or

Pagina 6 - List of Figures

xiii AM4210www.kontron.comRegulatory Compliance StatementsFCC Compliance Statement for Class B DevicesThis equipment has been tested and found to comp

Pagina 7 - List of Tables

xiv AM4210www.kontron.comLimited WarrantyKontron grants the original purchaser of Kontron's products a TWO YEAR LIMITED HARDWARE WARRANTY as desc

Pagina 8 - Safety Instructions

1AM4210Chapter 1Product Descriptionwww.kontron.com1.1 Product Overview...21.2 What’s Included ...

Pagina 9

2AM4210www.kontron.com1. Product Description1.1 Product OverviewThe AM4210 is an Advanced Mezzanine Card (AMC) from Kontron supporting both multi-core

Pagina 10 - Safety Requirements

3AM4210www.kontron.com1.2 What’s IncludedThis board is shipped with the following items: • One AM4210 AMC board• One DB9 to RJ45 adaptor• One Document

Pagina 11 - Customer Comments

4AM4210www.kontron.comStandards Compliance• This board is compatible to the following standards:• AMC.0 R2.0 Advance Mezzanine Card Base Specification

Pagina 12 - Advisory Conventions

iAM4210www.kontron.comRevision HistoryCustomer ServiceVisit our site at: www.kontron.com © 2010 Kontron, an International Corporation. All rights rese

Pagina 13 - Unpacking

5AM4210www.kontron.com1.4 Hot Swap CapabilityThe AMC supports Full Hot Swap capability as required by AMC.0 R2.0. It can be removed from or installed

Pagina 14 - CE Certification

6AM4210www.kontron.com1.5 Software SupportThe following table contains information related to software supported by the AM4210.Table 1-2: AM4210 Softw

Pagina 15 - Limited Warranty

7AM4210Chapter 2Board Featureswww.kontron.com2.1 Block Diagram ... 82.2 System Core ...

Pagina 16 - Product Description

8AM4210www.kontron.com2. Board Features2.1 Block DiagramFigure 2-1: Block Diagram

Pagina 17 - 1. Product Description

9AM4210www.kontron.com2.2 System Core2.2.1 Cavium OCTEON Plus 5650• 12x MIPS64 R2 Cores; 600Mhz • Up to 14.4 Billion MIPS64 instructions per second• 1

Pagina 18 - 1.3 Board Specifications

10 AM4210www.kontron.com2.4 SFP+ Front IOThe front SFP+ cage support multi-rate fiber SFP+ module.Table 2-1: SFP+ ConnectionSFP+ module is not provide

Pagina 19

11 AM4210www.kontron.comExternal connection is established with a straight through Ethernet cable and a RJ45 (female) to SubD (female) adapter if requ

Pagina 20 - 1.4 Hot Swap Capability

12 AM4210www.kontron.com2.9 AMC ConnectorTable 2-3: AMC ConnectorPort Region Connection0 GbE GbE eth01 GbE GbE eth12 Storage -3 Storage -4 Fat Pipe PC

Pagina 21 - 1.5 Software Support

13 AM4210www.kontron.com2.10 Front Panel LEDsFigure 2-2: Front Panel of AM42102.10.1 Hot Swap LED (Blue LED)The AM4210 board supports a blue Hot Swap

Pagina 22 - Board Features

14AM4210Chapter 3Chapter 3Installing the Boardwww.kontron.com3.1 Hot Swap Insertion Procedures... 153.2 Hot Swap Ext

Pagina 23 - 2. Board Features

Table of Contentsii AM4210www.kontron.comTable of ContentsSafety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 24 - 2.3 USB Flash Module

15 AM4210www.kontron.com3. Installing the Board3.1 Hot Swap Insertion ProceduresThe AM4210 is designed for hot swap operation. Hot swapping allows th

Pagina 25 - 2.4 SFP+ Front IO

16 AM4210www.kontron.comLED will be turned off. If the module FRU information is invalid or the carrier cannot provide the necessary payload power, th

Pagina 26 - 2.8 Power Supply

17 AM4210www.kontron.com3.3 SoftwareThe AM4210 comes as a pre-installed system with all necessary OS, Filesystem, drivers and applications factory-ins

Pagina 27 - 2.9 AMC Connector

18 AM4210www.kontron.com3.4.2 RTM serial connectionThe serial console of the AM4210 can be accessed via RTM. The RTM to be used depends on the carrier

Pagina 28 - 2.10 Front Panel LEDs

19 AM4210www.kontron.comBusyBox v1.2.1 (2008.09.15-08:10+0000) Built-in shell (ash)Enter 'help' for a list of built-in commands.~ #3.4.3 Acc

Pagina 29 - Installing the Board

20 AM4210www.kontron.com 0x00 0x00 0x00~ #Check LAN settings on the Ethernet interface to be configured for IOL (optional). Default settings

Pagina 30 - 3. Installing the Board

21 AM4210www.kontron.com3.4.4.3 Configure SoLThe Linux host must now be configured to connect to eth0 (AMC port 0) of the AM4210. This is dependant on

Pagina 31 - 16 AM4210

22 AM4210www.kontron.comAdjust serial baud-rate to 115.2 kBaud (required):[root@router01 ipmitool-1.8.9]# src/ipmitool -I lanplus -H 10.0.1.145 -U adm

Pagina 32 - 3.4 System access

23 AM4210www.kontron.com/sbin/rc startingUpdating module dependenciesLoading IPv6 moduleMounting file systemsSetting up loopbackStarting syslogdJan 1

Pagina 33 - 3.4.2 RTM serial connection

24 AM4210www.kontron.com3.5.1 Usagecfgtool [--help|-h][--status|-t][--interface|-i][--pcie|-p][--clock|-k][--set|-s][--cycle|-c][--nofru|-n][--debug|-

Pagina 34 - 3.4.4.1 Requirements

Table of Contentsiii AM4210www.kontron.com3. Installing the Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35

25 AM4210www.kontron.com• -n | --nofruThis option prevent FRU data update when changing an interface, pcie, or clock setting (obsolete)• -d | --debugT

Pagina 36 - 3.4.4.3 Configure SoL

26AM4210Chapter 4Thermal Considerationswww.kontron.com4.1 Thermal Monitoring ... 274.2 External Therma

Pagina 37

27 AM4210www.kontron.com4. Thermal Considerations4.1 Thermal MonitoringTo ensure optimal operation and long-term reliability of the AM4210, all onboar

Pagina 38 - 3.5 Using the cfgtool

28 AM4210www.kontron.comTable 4-1:MMC Temperature Sensors ThresholdsTemperature values are measured with an accuracy of 1°C.4.2 External Thermal Regul

Pagina 39 - 3.5.1 Usage

29 AM4210www.kontron.com4.2.2.1 How to read the diagramThe diagram contains one curve for 80% thermal load and one for 100%. Full thermal load is not

Pagina 40 - 25 AM4210

30 AM4210www.kontron.com4.2.3 Airflow ImpedanceIn order to determine the cooling requirements of the AM4210, the airflow impedance of the module has b

Pagina 41 - Thermal Considerations

31 AM4210www.kontron.comTable 4-2:Deviation of the Airflow Rate on the AM4210Inlet Velocity Deviation (%)CFM m/s LFM ZONE A ZONE B ZONE C ZONE D5 0.57

Pagina 42 - 4. Thermal Considerations

Chapter 5Chapter 5Software Setupwww.kontron.com5.1 MMC Firmware... 335.2 Bootloader...

Pagina 43 - 4.2.1 Forced Airflow

33 AM4210www.kontron.com5. Software SetupSoftware on the AM4210 includes the following parts:• Bootloader• OS (rootFS, kernel)• MMC FW5.1 MMC Firmware

Pagina 44 - 4.2.2.2 Airflow

34 AM4210www.kontron.com5.1.2 IPMI SensorsThe MMC includes many sensors for voltage or temperature monitoring and various others for pass/fail type si

Pagina 45 - 4.2.4 Airflow Paths

Table of Contentsiv AM4210www.kontron.com5.3 Board Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - 31 AM4210

35 AM4210www.kontron.com5 B1:IPMBL State C3h (OEM Kontron)6Fh (Sensor Specific)For additional information, refer to section Kontron IPMB-L Link

Pagina 47 - Software Setup

36 AM4210www.kontron.com12 B1:Temp Air Out 01h (Temperature)01h (Threshold Based)Temperature Sensor of the outlet regionSensor is only readable when

Pagina 48 - 5. Software Setup

37 AM4210www.kontron.com27 B1:Pres SFP-3 25h (Entity Present)6Fh (Sensor specific)The sensor shows presents or absents of SFP. No event is generate

Pagina 49 - 5.1.2 IPMI Sensors

38 AM4210www.kontron.com5.1.2.1 OEM sensor description5.1.2.1.1 Kontron FRU Info AgentTable 5-2:Kontron FRU info agent sensorEvent/Reading type codeSe

Pagina 50 - 35 AM4210

39 AM4210www.kontron.com5.1.2.1.2 Kontron IPMB-L Link5.1.2.1.3 Kontron MMC Firmware Upgrade StatusTable 5-3:Kontron IPMB-L Link sensorEvent/Reading ty

Pagina 51 - 36 AM4210

40 AM4210www.kontron.com5.1.2.1.4 Kontron Reset5.1.2.1.5 Kontron POST Code Value5.1.2.1.6 Kontron Diagnostic StatusTable 5-5:Kontron reset sensorEvent

Pagina 52 - 37 AM4210

41 AM4210www.kontron.com5.1.2.1.7 Kontron User SW upgradeStatus5.1.2.2 Sensor ThresholdsFollowing table shows sensor thresholds for voltagesTable 5-8:

Pagina 53 - Event trigger

42 AM4210www.kontron.com5.1.3 OEM commands5.1.3.1 OEM Get Firmware SysUpTime5.1.3.2 OEM Get Serial ConfigurationExample: Using onboardipmitool –l 3 ra

Pagina 54

43 AM4210www.kontron.com5.1.3.3 OEM Set Serial ConfigurationExample: Using onboardipmitool –l 3 raw 0x30 0x06 0xab 0xca 0xca 0xce 0xc9 <setting>

Pagina 55

44 AM4210www.kontron.comExample: Using onboard # ipmitool raw 0x3e 0x20 <ID> <STATE>Example: Using ipmitool on Kontron AMC carrier (e.g. A

Pagina 56 - 5.1.2.3 Health Error

List of FiguresvAM4210www.kontron.comList of FiguresFigure 2-1: Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 57 - 5.1.3 OEM commands

45 AM4210www.kontron.com5.1.3.5 OEM Get Control StateExample:ipmitool –l 0 raw 0x3e 0x21 0x005.1.4 Field Replaceable Unit (FRU) InformationThis FRU in

Pagina 58 - 5.1.3.4 OEM Set Control State

46 AM4210www.kontron.com5.1.6 WatchdogThe complete startup and execution process is guarded using external watchdog timers implemented by the hardware

Pagina 59 - Example: Using onboard

47 AM4210www.kontron.com5.1.8.1 MMC Firmware Update using ipmitoolPrerequisites: a working TFTP server, DHCP server and network connectivity to the DH

Pagina 60 - 5.1.5 E-Keying

48 AM4210www.kontron.com5.1.9.1 MMC Firmware Update using IOL SessionTo setup an IOL session, please refer to chapter 3.4.3.2. The update will be done

Pagina 61 - 5.1.8 Updating MMC Firmware

49 AM4210www.kontron.comTable 5-10:Bootloader POST Code values5.2.2 Bootloader shell and optionsThe boot process can be interrupted by entering the bo

Pagina 62

50 AM4210www.kontron.comdataXa_flash_update ScriptCommand script to flash a binary image transferred with tftpboot to the active image flash partitio

Pagina 63 - 5.2 Bootloader

51 AM4210www.kontron.comThere are 3 different types of bootloader environment variables:• Script: The variable is a set of consecutive (more simple) b

Pagina 64 - 49 AM4210

52 AM4210www.kontron.com• Var: The variable controls a specific behavior of the bootloader startup sequence. E.g. the ‘bootdelay’ variable controls th

Pagina 65 - 50 AM4210

53 AM4210www.kontron.com5.2.3.1 Update from Bootloader CLIThe following procedure defines the update of the image 0 bootloader:• Start system and conn

Pagina 66 - 51 AM4210

54 AM4210www.kontron.com5.2.3.2 Update from WindRiver Linux ShellTo update the boardloader along with the Linux kernel BSP using the kex-flashimage to

Pagina 67 - 5.2.3 Bootloader Update

List of Tablesvi AM4210www.kontron.comList of TablesTable 1-1 Board Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 68

55 AM4210www.kontron.comWhen shipped from factory, image0 and image1 contain identical bootloader and firmware images and image0 system is booted by d

Pagina 69 - 5.3 Board Firmware

56 AM4210www.kontron.com5.3.1.2 Image swap using ipmitoolImage swap can also be achieved using the ipmitool from the Linux shell of the board. The fol

Pagina 70 - Size Linux parti

57 AM4210www.kontron.com5.3.3 Cavium Linux BSP5.3.3.1 Rebuilding the Cavium Linux BSPCavium Networks provides a SDK that includes Linux kernel and roo

Pagina 71 - 5.3.2 Updating Firmware

58 AM4210www.kontron.comIn case ‘quilt’ is not installed, use ‘patch’ instead:# for i in `cat patches/series`; do patch -p 1 < patches/$i; donePlea

Pagina 72 - 5.3.3 Cavium Linux BSP

59 AM4210www.kontron.comKCS: Reading boot image number : Image 0KCS: Reading interface settings: front x1 XAUI, p8..11 x4 GEKCS: Reading PCIe settings

Pagina 73

60 AM4210www.kontron.com5.3.3.3 Updating JFFS2 partitionThere are two Linux MTD partitions (mtd4 for image 0 and mtd9 for image 1) available that allo

Pagina 74

61 AM4210www.kontron.comAfter the build process has been finished, the (stripped) kernel image is stored in the export directory ‘kontron_t5516-vmlinu

Pagina 75 - 5.3.4 WindRiver Linux BSP

62 AM4210www.kontron.comThis will update flash image1 firmware, MMC firmware and FRU data in case that the old version is GA 2.04 or higher. Please re

Pagina 76

63 AM4210www.kontron.comThis will update flash image0 firmware to GA 2.05, but not MMC firmware and FRU data of the board. However, after rebooting to

Pagina 77

64 AM4210www.kontron.com• Copy the kernel built in step 1 into the tftpboot directory of the development host. E.g. the kernel for the WindRiver Linux

Pagina 78 - 5.3.6 Using the NFS Root FS

vii AM4210www.kontron.comSafety InstructionsBefore You BeginBefore handling the board, read the instructions and safety guidelines on the following pa

Pagina 79

A-1 AM4210www.kontron.comA. Connectors PinoutsA.1 USB SSD Flash ModuleA.2 SFP+ Front IOSignal Pin Number Signal Pin NumberV_5V 1 NC 2USB DATA (-) 3 NC

Pagina 80 - A. Connectors Pinouts

A-2 AM4210www.kontron.comA.3 Serial Port PinoutA.4 Serial console terminal cable interface: RJ45 Female to DB9 FemaleSignal PinRTS 1DTR 2TXD 3GND 4GND

Pagina 81 - RJ45 Female to DB9 Female

B-1 AM4210www.kontron.comB. Getting HelpIf, at any time, you encounter difficulties with your application or with any of our products, or if you simpl

Pagina 82 - B. Getting Help

B-2 AM4210www.kontron.comB.1 Returning Defective MerchandiseBefore returning any merchandise please do one of the following:• Call1 Call our Technical

Pagina 83 - B-2 AM4210

B-3 AM4210www.kontron.comB.2 When Returning a Unit• In the box, you must include the name and telephone number of a contact person, in case further ex

Pagina 84 - B.2 When Returning a Unit

C-1 AM4210www.kontron.comC. GlossaryAcronyms DescriptionsACL Access Control List. IP Access Control List.ACPI Advanced Configuration & Power Inter

Pagina 85 - C. Glossary

C-2 AM4210www.kontron.comCRC Cyclic Redundancy CheckCS1 Components Side 1 as describes in PICMG3.0.CS2 Components Side 2 as describes in PICMG3.0.CTCA

Pagina 86 - C-2 AM4210

C-3 AM4210www.kontron.comFRBxFault-Resilient Booting level [1-3]. A term used to describe system features and algorithms that improve the likelihood o

Pagina 87 - C-3 AM4210

C-4 AM4210www.kontron.comIPM Intelligent Platform ManagementIPMB Intelligent Platform Management BusIPMB-0 Intelligent Platform Management Bus Channel

Pagina 88 - C-4 AM4210

C-5 AM4210www.kontron.comMP MultiProcessorMPS MultiProcessor SpecificationMRCMemory Reference Code. Chipset specific code provided by the manufacturer

Pagina 89 - C-5 AM4210

viii AM4210www.kontron.comPreventing Electrostatic DischargeStatic electricity can harm system boards. Perform service at an ESD workstation and follo

Pagina 90 - C-6 AM4210

C-6 AM4210www.kontron.comRHEL Red Hat Enterprise LinuxRMS Root Mean SquareRoHS Restriction of the Use of Certain Hazardous SubstancesROMRead Only Memo

Pagina 91 - C-7 AM4210

C-7 AM4210www.kontron.comSSHSecure SHell. A network protocol that allows data to be exchanged over a secure channel between two computers.TCLKA Teleco

Commenti su questo manuale

Nessun commento